Measurement amplifier U amplifies low-amplitude measurement signals from low-resistance signal sources for measurement with any chosen voltmeter or oscilloscope. By using an external shunt resistor it is also possible to measure small currents. Offset voltages can be compensated using coarse and fine offset adjustment knobs. Amplification (gain) can be selected in ranges from 0 to 5 powers of ten. High-frequency noise or other interference signals are filtered out by means of a low-pass filter with step-wise selectable time constants between 0 and 3 seconds. The output voltage has the same sign as the input voltage.

Input resistance:                             10 kohm
Output resistance:                          300 ohm
Offset voltage drift:                          < 2 μV/K (after 15 mins.
operation approx.)
Gain factors:                                    100; 101; 102; 103; 104; 105
Tolerance for gain factors:            < 2.5 %
Input voltage:                                   max. ±12 V  
(overload protected for
brief transients up to 100 V)
Output voltage:                                0 … ±12 V
(short-circuit protected)
Power supply (via
plug-in supply provided):               12 V AC
Ambient temperature:                     5°C ... 23°C … 40°C
Storage temperature:                      -20 … 70°C
Relative humidity:                           <85%
no condensation
Operational alignment:                  Horizontal
Contamination level:                      2
Protection class:                              IP20
Dimensions:                                    170x105x50 mm3 approx.
Weight:                                             335 g approx.


Measurement and frequency ranges (relative to 1 V output voltage)

Gain Input voltage Current through
RShunt = 100 ohm
Frequency
100 1 V 10 mA 0 … 25 kHz
101 100 mV 1 mA 0 … 25 kHz
102 10 mV 100 µA 0 … 25 kHz
103 1 mV 10 µA 0 … 20 kHz
104 100 µV 1 µA 0 … 7 kHz
105 10 µV 100 nA 0 … 7 kHz
 

Cut-off frequency for switchable low-pass filter

Time constant Cut-off frequency
0.0 s See Table 1
0.1 s 1.6 Hz
0.3 s 0.5 Hz
1.0 s 0.16 Hz
3.0 s 0.05 Hz

  • Secure online payment with SSL
  • Expert advice
  • Financing available
  • Easy returns & exchanges
  • International shipping available
  • Features :

    • Hygienic Product : Not Specified
    • Allergy : Not Specified
    Measurement Amplifier U (115 V, 50/60 Hz) - 1020744
    • UPC:Not Specified
    • GTIN/ITF Barcode : Not Specified
    • Units of Measure : Not Specified
    • Overall Product Length : Not Specified in
    • Overall Product Width : Not Specified in
    • Overall Product Height : Not Specified in
    • Weight Capacity : Not Specified lbs
    • Actual Product Weight : 1.63
    • Product Assembly : Not Specified
    • Product Installation : Not Specified
    • Country of Origin : Not Specified
    • Case QTY : Not Specified/case
    • Case Weight : Not Specified
    • Ships Via Freight : No
    • Proposition 65 Warning : Not Specified
    Measurement Amplifier U (115 V, 50/60 Hz) - 1020744
    Measurement Amplifier U (115 V, 50/60 Hz)

    Measurement Amplifier U (115 V, 50/60 Hz)

    MRP: $774.56

    Measurement Amplifier U (115 V, 50/60 Hz) - 1020744

    Measurement amplifier U amplifies low-amplitude measurement signals from low-resistance signal sources for measurement with any chosen voltmeter or oscilloscope. By using an external shunt resistor it is also possible to measure small currents. Offset voltages can be compensated using coarse and fine offset adjustment knobs. Amplification (gain) can be selected in ranges from 0 to 5 powers of ten. High-frequency noise or other interference signals are filtered out by means of a low-pass filter with step-wise selectable time constants between 0 and 3 seconds. The output voltage has the same sign as the input voltage.

    Input resistance:                             10 kohm
    Output resistance:                          300 ohm
    Offset voltage drift:                          < 2 μV/K (after 15 mins.
    operation approx.)
    Gain factors:                                    100; 101; 102; 103; 104; 105
    Tolerance for gain factors:            < 2.5 %
    Input voltage:                                   max. ±12 V  
    (overload protected for
    brief transients up to 100 V)
    Output voltage:                                0 … ±12 V
    (short-circuit protected)
    Power supply (via
    plug-in supply provided):               12 V AC
    Ambient temperature:                     5°C ... 23°C … 40°C
    Storage temperature:                      -20 … 70°C
    Relative humidity:                           <85%
    no condensation
    Operational alignment:                  Horizontal
    Contamination level:                      2
    Protection class:                              IP20
    Dimensions:                                    170x105x50 mm3 approx.
    Weight:                                             335 g approx.


    Measurement and frequency ranges (relative to 1 V output voltage)

    Gain Input voltage Current through
    RShunt = 100 ohm
    Frequency
    100 1 V 10 mA 0 … 25 kHz
    101 100 mV 1 mA 0 … 25 kHz
    102 10 mV 100 µA 0 … 25 kHz
    103 1 mV 10 µA 0 … 20 kHz
    104 100 µV 1 µA 0 … 7 kHz
    105 10 µV 100 nA 0 … 7 kHz
     

    Cut-off frequency for switchable low-pass filter

    Time constant Cut-off frequency
    0.0 s See Table 1
    0.1 s 1.6 Hz
    0.3 s 0.5 Hz
    1.0 s 0.16 Hz
    3.0 s 0.05 Hz

  • Secure online payment with SSL
  • Expert advice
  • Financing available
  • Easy returns & exchanges
  • International shipping available
  • Features :

    • Hygienic Product : Not Specified
    • Allergy : Not Specified

    Measurement Amplifier U (115 V, 50/60 Hz) - 1020744
    • UPC:Not Specified
    • GTIN/ITF Barcode : Not Specified
    • Units of Measure : Not Specified
    • Overall Product Length : Not Specified in
    • Overall Product Width : Not Specified in
    • Overall Product Height : Not Specified in
    • Weight Capacity : Not Specified lbs
    • Actual Product Weight : 1.63
    • Product Assembly : Not Specified
    • Product Installation : Not Specified
    • Country of Origin : Not Specified
    • Case QTY : Not Specified/case
    • Case Weight : Not Specified
    • Ships Via Freight : No
    • Proposition 65 Warning : Not Specified

    Measurement Amplifier U (115 V, 50/60 Hz) - 1020744